GEK Wiki / Pressure Instrumenation
  • If you are citizen of an European Union member nation, you may not use this service unless you are at least 16 years old.

  • You already know Dokkio is an AI-powered assistant to organize & manage your digital files & messages. Very soon, Dokkio will support Outlook as well as One Drive. Check it out today!

View
 

Pressure Instrumenation

Page history last edited by jim mason 14 years, 5 months ago

 

Every GEK kit comes with a two channel manometer that fixes to the front of the gas cowling.  Pictures of the GEK manometer installed are here: http://allpowerlabs.org/gasification/gek/images/v2.0/v2.0gallerynewmanometer.html . This manometer is easy to make yourself, using the files and instructions below.  There are also specific install instructions for how to mount and plumb it on your GEK in the GEK assembly instructions towards the bottom of the page.  http://gekgasifier.pbworks.com/Assembly-Instructions-GEKv3-LevelV-kits

 

We stopped using dial inches of h2o gauges with v2.0 as they are easy to foul with tar and break on overpulls.  Given the gauges cost $40-$50 reach, and you need two of them, we figured out a cheaper and more robust solution.  Thus the simple CNC plasma cut manometer seen below. 

 

This manometer reads (-20) - 0 (+20)  inches of water.  The tube plumbing should be 1/4"ID clear tubing.  Ends are terminated to 1/8" brass barbs that screw into some plumbing bung at the measure point.  The two measure points we use are "reactor drop" measured in the gas cowling at grate level.  And "total filter train and reactor drop" measured at the end of top of the packed bed filter.

 

You can fill the manometer with any watery fluid.  We use coffee so we can see it.  Also, then we can call out readings with statements like "we're reading about 4 inches of coffee, Joe".  Grape juice would work nice too.  As would dark beer.

 

 

 

Full Res files are findable here:

ManometerCADnumbersCut.pdf

ManometerCADnumbersCut.dxf

 

 

ManometerCADnumbersCut.dwg

ManometerCADnumbersCut.iges

ManometerCADnumbersCut.eps

 

Electronic Pressure Sensors (GCU Compatible)

Freescale Model Number

Min Meas. Pressure (kPa)

Max Meas. Pressure (kPa)

Max Tolerance (kPa)

 

MPXV7002DP (GCU)

-2

+2

75 (highly suspect)

 

MPXV5004DP

0

+4

16

 

MPXV4006DP

0

+6

24

 

MPXV7007DP (GCU)

-7

+7

75

 

MPXV5010DP

0

+10

75

 

MPXV7025DP

-25

+25

200

 

MPXV5050DP

0

+50

200

1 kPa = 4.014 inH2O

1 kPa =  0.145 psi (50 kPa = 7.25 psi)

(would require soldering and changes to code to handle new pressure ranges)

Comments (0)